System Software Control
Features
- Standard compliant TL-1
Command Line Interface
- Auto-provisioning of all
modules during installation and initialization
- Upon insertion of a
replacement module:
Automated Hardware and Software compatibility checks
Automated Software download of current module software
Auto-provisioning from current provisioning database
- Inventory in software:
Input reference source
Output port assignment
Inventory CLEI and Mfg Serial Number in software to help in field
servicing and PCN administration
Modular Redundancy in
Hardware
- Dual Power Inputs &
Power Supplies
- Up to 5 References
Inputs
- Inputs bridge to both
IOP Modules
- Dual IOP’s (ST-2 or
ST-3E)
- Paired Output Modules
for 1 to 1 Protection
Microprocessor Control &
Memory Features
- Top level IntelTM
microprocessors on COM and both IOP modules
- System Databases stored
on the COM module are backed up on BOTH IOP’s
- Output Module on-board
microprocessors enable management to each output port
Oscillator Options
- Standard Quartz ST-3E &
Rubidium ST-2
- Optional Stratum 2 High
Precision Double Oven Quartz Oscillator (DOCXO) - ST- 2
performance at lower cost
System Communications
Interfaces
- Local craft interfaces—2
( 1 front panel)
- TCP / IP Local Area
Network interface via RJ-45
Integrated GPS Receiver
The US5GM is designed to
integrate GPS receiver. This arrangement optimizes rack bay
utilization by eliminating separately mounted GPS unit. The
GPS reference is independent of other input capacity meaning
all other inputs are still
available for selection or for monitor only operation.
Alarm Reporting Modes
- Module Status and Alarm
LED’s
- 6 Contact Closure
Relays—Local & Remote
- TL-1 Autonomous Output
Messaging
- 16 Discrete Alarm Input
Relays
Architecture
Main shelf
module : 2 clocks with maximum 3 inputs each, GPS, 4 output
cards (80 1+1 max output ports)
Fast interface bus for inter-cards communication
Local and remote management; software download for all active
module (IOP modules, COM card, Output Cards)
Safe Data Base management; duplication of Data base on COM
card and on both clock modules
Power supply modules
Dual load
sharing
Each receives power from dedicated back panel power input
Automatic redundancy in case of module failure
Dual -35 to -72VDC
Communication Module (COM
card)
System
Communications Controller -BOTH external and internal
processes
Provides system TL-1 Agent
Manages all system security processes
Manages all DB storage, access & synchronisation with IOP
back up
Powerful CPU with real time kernel.
2 RS232: CRAFT 1,2
1 ETHERNET RJ45: 4x TELNET + 6x TCP/IP sessions
EVENT LOG (1000)
EVENT AO LOG (400)
SECU LOG (100)
DBCHG LOG (400)
Performance measurement : buffering, log and alarm for Clock
module PM data
Clock modules (IOP
modules)
Based on
Rubidium or quartz oscillator, possibility of mixed
configuration
Dual redundant clock modules
Clock performance : ITU-T G.812 type 1 & 2 or ANSI T1.101
type ST2 or ST3E
5 Universal input modules : E1, 2048 kHz, 1-5-10 MHz, (option
1544 kHz, DS1, 64 kHz CC)
Maximum 5 input modules per clock module (input impedance 75
and 120 Ohm)
Each input can be used as reference or measurement input
SSM: full compliant (ITU-T G.704, Telcordia GR-378),
possibility of QL assignment for no SSM capable inputs
Full software manageable: diagnostic alarms, automates for
clock state administration
Powerful CPU with real time kernel
Performance Measurement : TIE, MRTIE, TDEV, FFOFF for several
time intervals (1s to 10000s)
GPS
Two
plug-in GPS receivers
Optionally, antenna converter allowing to use 300m of RG59
cable to connect the antenna
Output
40 or 20
outputs per module, paired for 1+1 protection
E1 2MHz-2Mbit/s programmable or T1-CC programmable
Main shelf: 80 outputs max (1+1 protected)
Environmental
Operating
temperature: -5° to 50°c
Humidity: 5 to 95%
Dimensions: H=270mm(10.5"); W=430mm(17"); D=280mm(11")