Printer Friendly
Data Sheet (pdf) |
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
UNISync
5G-A™
Synchronization Supply Unit Main Shelf |
|
|
|
|
FEI, with a 45-year legacy in precision
oscillator technologies and more than 20
years of experience designing and
manufacturing SSU’s for major
international carriers, has created an SSU of
unprecedented reliability, durability, survivability,
adaptability, and cost efficiency. |
|
|
Total Software Management means
that for the first time, no dedicated hardware assemblies,
jumpers, or switches are used to configure common telecom
signal formats in the UNISync 5G-A - inbound or outbound.In addition, all software
management interfaces are remotely accessible via TCP/IP LAN
allowing full utilization of Centralized Network Operations
Center (CNOC) for alarm monitoring and management.
The US5G-A operates with Intel™
microprocessors on the Com and both IOP modules. The Com
module is the primary home for all system databases, but
DB's are backed up to both IOP modules. Microprocessors on
the output modules enable provisioning and alarm management
to the port level. |
| |
|
|
| |
Product Specifications |
|
| |
|
|
| |
|
US5G-A
Shelf Modules: |
|
|
|
Power
Supply Modules: |
- Dual
load sharing
- Each
receives power from a dedicated back
panel power input
-
Automatic redundancy in case of
module failure
-
Front panel fuses and power status
LED's
|
|
Communication
Module: |
-
US5G-A System CPU
-
System Communications Controller -
BOTH external and internal Com
processes
-
Provides system TL-1 Agent
-
Manages all system security
processes
-
Manages all DB storage, access, and
synchronization with IOP back up
|
|
Input/Output/Processor
Module: |
- Dual
Clock Modules
-
Input Capacity - up to 10 inputs
- Dual
System DB Back Up to the
Com module
|
|
Output
Module: |
-
Paired in adjacent slots for 1 to 1
output protection
-
Outputs are software assignable
for
DS-1/CC
-
Inventory Port Assignments in
Software
-
Alarm visibility to the port level
|
|
NTP
Client/Server Module: |
- Slot
compatible - Main/Exp
- Back
Panel I/O Fixture adapts to existing
DB-25 sockets
-
Gigabit Ethernet Interface
- NTP
v4.2.4
|
|
PTP
IEEE-1588 Module: |
- Slot
compatible - Main/Exp
- Back
Panel I/O Fixture adapts to existing
DB-25 sockets
-
Gigabit Ethernet Optical SFP - Front
-
Electrical Outputs - Rear
|
|
|
Input / Output
Capacity: |
|
|
|
US5G-A
Inputs: |
-
Termination - Wire wrap on back
panel
-
Bridged - Each input to both IOP
modules
-
Inputs are software assignable CC,
DS1 (SF/ESF), E-1, 1, 5, or 10 MHz
- User
Selectable Priority Options -
Priority 1 to 10
- Up
to 10 Inputs on each IOP module
-
Selectable SSM activation - Gen 1 or
Gen 2
|
|
US5G-A
Ouputs: |
- 40
outputs per module, paired for
1 to1 protection
- Main
Shelf capacity - 160 outputs
-
Expansion capacity - 4 Expansion
Shelves, 320 outputs per shelf
-
Total system capacity - 1440 outputs
|
|
Performance
Monitoring: |
-
Simultaneous Data Collection on all
Inputs
- Data
Metrics - Frequency Offset, TIE,
MRTIE, TDEV, LMRTIE
-
Average Periods - from 10 - 100,000
sec.
|
|
Communication
and Management: |
| |
|
Craft/Local
Ports: |
- 1
RJ-45 Ethernet
-
3-pin terminations for output alarms
-
3 Major, 3 Minor (NC/NO)
|
|
Software
Interface: |
-
Standards compliant TL-1 agent
- GUI
Interface
|
|
Standards
Compliance: |
- NEBS
Level III - testing and evaluation
by Telcordia Labs
- All
Telcordia GR standards covering
TSG'S, oscillators and network
equipment - validated by Telcordia
Labs
|
|
 |
|
| |
|
|
| |
|
|
| |
UNISync
5G Expansion Shelf |
|
| |
|
|
| |

UNISync
5G Expansion Shelf |
|
| |
|
|
| |
US5G
Manager™ - Graphical User Interface |
|
| |
|
|
| |
|
|
| |
 |
|
| |
|
|
| |
|
|
|