Time Code Output Modules
 

 
 

Description Part No.  
 



Time Code Module - IRIG A, IRIG B, NASA 36 or 2137, RS-232 Time of Day (TOD) serial output, IEEE 1344-1995, AM or DC code output. One 9 pin DE-9 and two BNC connectors. Two status LED's. 385-4020-12  
         
 



Time Code Module - IRIG A, IRIG B, NASA 36 or 2137, IEEE 1344-1995,
AM or DC code output. Four BNC connectors. Two status LED's.
385-4020-11  
         
 



Time Code Module - IRIG A, IRIG B, NASA 36 or 2137, RS-422, IEEE 1344-1995. One 9 pin DE-9 and two BNC connectors. Two status LED's.

(AM or DC code output on BNC connectors only).
385-4020-13  
 
 
 



IRIG Input Module -  Time Code Input Module has connections for IRIG-B input (time information), and connections for external synchronization input. The IRIG-B input and synchronization input signals are used to set the time and discipline DTF-based systems. Four BNC connectors, six status LED's. 385-4040-01  
         
 



IRIG Input Module - Time Code Input Module has connections for IRIG-B input (time information), and connections for a RS-232 serial command port. The 385-4040-03 module may also be used in conjunction with the 385-4038-02 or -03 Ethernet input module, when installed in an adjacent slot. One DE-9 connector, two BNC connectors, four status LED's. 385-4040-03  
 
 
 



Have Quick Time Code Module -  Provides Have Quick time as well as other required signals. Two DE-9 female connectors, each with identical outputs. Two status LED's. 385-4070-01  
         
 



PTTI/Have Quick Time Code Module -  Provides PTTI/Have Quick time as well as other required signals. Two DE-9 female connectors, each with identical outputs. Two status LED's. 385-4070-02  
         
 



PTTI Time Code Module - Provides BCD time 1PPS and 1PPM outputs. Three BNC connectors. Two status LED's. 385-4074-01  
 
 
 



Dual NTP Output Module - provides two independent Ethernet ports
that provide Network Time Service using NTP (Network Time Protocol) or SNTP. Two RJ-45 connectors. Six status LED's.
385-4087-01  
         
 



T1/E1 Output Module - The T1/E1 Quad Output Module provides four all 1’s outputs in T1/DS1 D4, T1/DS1 ESF (Extended Super Frame) or E1 formats. 4 RJ-45 connectors. Two status LED's. 385-4034-01  
         
 



T1/E1 Output Module - The T1/E1 Quad Output Module provides four all 1’s outputs in T1/DS1 D4, T1/DS1 ESF (Extended Super Frame) or E1 formats. 4 BNC connectors. Two status LED's. 385-4034-02  
         
 



T1/E1 Output Module - The T1/E1 Quad Output Module provides four all 1’s outputs in T1/DS1 D4, T1/DS1 ESF (Extended Super Frame) or E1 formats. 2 9 pin DE-9 connectors. Two status LED's. 385-4034-03  
         
 



T1/E1 Output Module - The T1/E1 Quad Output Module provides four all 1’s outputs in T1/DS1 D4, T1/DS1 ESF (Extended Super Frame) or E1 formats. Wire-wrap outputs. Two status LED's. 385-4034-04  
         
   

 

     
         